Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing SystemKeine Angabe
KPA15
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System
Keine Angabe
KPA15
VB plus PDV
2.100 €
Stanje
Polovno
Lokacija
Borken 

Osnovni podaci
- Oznaka mašine:
- Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System
- Proizvođač:
- Keine Angabe
- Model:
- KPA15
- Stanje:
- polovno
Cena i lokacija
VB plus PDV
2.100 €
- Lokacija:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Pozvati
Detalji ponude
- ID oglasa:
- A405-0120
- Referentni broj:
- 20560
- Ažuriranje:
- последњи пут дана 03.11.2026
Opis
Betschart Swiss Transformer Core Testing System KPA 15 – Isolation Transformer Test Core Testing System
Function
The output voltage, which can be continuously adjusted manually by means of a rotary knob, is directly applied to the excitation coils of the test core.
This is intended to create a homogeneous electromagnetic field in the air gap of the test core, with which core material inserted into the air gap can be characterized.
The basic operation of the core testing system is performed via the switch and display elements on the front panel at the front of the test carriage.
Technical data
Input voltage: 2 x 400 V – 50/60 Hz
Input current: 38.3 A maximum
Output voltage: 0 … 230 V
Output current: 65 A maximum
Measurements: Moving-coil voltmeter 0 … 500V for input voltage
Moving-coil voltmeter 0 … 250V for output voltage
Moving-coil ammeter 0 … 40/80A for input current
Moving-coil ammeter 0 … 75/150A for output current
Laboratory sockets for external voltage measurement, direct, 1:1
Bljdpfod Nxhkox Ah Tsp
Circuit breaker, 2-pole, 63A, characteristic B
Voltage measurement, output voltage
Current measurement, output current
Voltage measurement, input voltage
Current measurement, input current
Laboratory sockets for external current measurement, current transformer 50A/5A
Current measurement, current transformer 75A/5A, output side
Main and emergency stop switch
Manufacturer’s price: €27,000 gross
Matching adjustable transformers can be found in our shop.
You can find more items – new and used – in our shop!
International shipping costs available upon request!
Oglas je automatski preveden. Moguće su greške u prevodu.
Function
The output voltage, which can be continuously adjusted manually by means of a rotary knob, is directly applied to the excitation coils of the test core.
This is intended to create a homogeneous electromagnetic field in the air gap of the test core, with which core material inserted into the air gap can be characterized.
The basic operation of the core testing system is performed via the switch and display elements on the front panel at the front of the test carriage.
Technical data
Input voltage: 2 x 400 V – 50/60 Hz
Input current: 38.3 A maximum
Output voltage: 0 … 230 V
Output current: 65 A maximum
Measurements: Moving-coil voltmeter 0 … 500V for input voltage
Moving-coil voltmeter 0 … 250V for output voltage
Moving-coil ammeter 0 … 40/80A for input current
Moving-coil ammeter 0 … 75/150A for output current
Laboratory sockets for external voltage measurement, direct, 1:1
Bljdpfod Nxhkox Ah Tsp
Circuit breaker, 2-pole, 63A, characteristic B
Voltage measurement, output voltage
Current measurement, output current
Voltage measurement, input voltage
Current measurement, input current
Laboratory sockets for external current measurement, current transformer 50A/5A
Current measurement, current transformer 75A/5A, output side
Main and emergency stop switch
Manufacturer’s price: €27,000 gross
Matching adjustable transformers can be found in our shop.
You can find more items – new and used – in our shop!
International shipping costs available upon request!
Oglas je automatski preveden. Moguće su greške u prevodu.
Dobavljač
Napomena: Besplatno se registrujte ili prijavite, da biste pristupili svim informacijama.
Registrovan od: 2008
531 Oglasi online
Pošalji upit
Telefon & Faks
+49 2862 ... oglasi
Vaš oglas je uspešno izbrisan
Došlo je do greške.